Conducted EMI test system combining third-party LISN and MSA.

[Application Example] By combining other companies' LISN and MSA series, it is possible to conduct conducted EMI tests for DC power supplies and three-phase power supplies.

The MR2150, a pre-compliance system for conducted EMI testing using MICRONIX's EMI measurement spectrum analyzer and signal analyzer, can utilize not only the MICRONIX MPW201B as the LISN but also LISNs from other manufacturers. By using LISNs from other manufacturers, the MR2150 can be used for products with DC power supplies, three-phase power supplies, and power supplies of 250V and 15A or more. 【Product Introduction】 ■ Conducted EMI Testing System MR2150 *For more details, please refer to the PDF materials or feel free to contact us.*

  • others
  • Conducted EMI Test System

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Conductive EMI Test System 'MR2150'

By conducting a debugging evaluation before this test, we can significantly reduce development costs.

The MR2150 is a pre-compliance system for conductive EMI testing. By using this system for debugging evaluation before conducting the official tests at an EMC site, you can significantly reduce development costs. Since the spectrum/signal analyzer, LISN, and PC software are all developed in-house, the overall usability and operational stability of the system have been thoroughly verified. Additionally, each component is reasonably priced, providing a cost-effective testing environment. 【Features】 ■ Provides a reasonable and cost-effective testing environment ■ Handheld spectrum/signal analyzers that can be selected based on budget and performance/features ■ Efficiency in EMI testing through rich software functionalities ■ Excellent portability of the LISN *For more details, please refer to the PDF materials or feel free to contact us.

  • others
  • Conducted EMI Test System

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Measurement accuracy of the conductive EMI test system MR2150.

Technical Data: Measurement Accuracy of MR2150 Compared to Compliance System

【Product Introduction】 ■Conductive EMI Test System MR2150 A system for pre-compliance testing of conductive EMI (noise terminal voltage). 1. Importance of EMC Pre-compliance Testing - The significance of EMC pre-compliance testing in product development - Comparison of pre-compliance testing with other EMC evaluation solutions 2. Measurement Accuracy Verification of MR2150 - EMI measurement accuracy of the Spectrum/Signal Analyzer MSA series - Conductive EMI testing of sample EUT - Appropriate measurement methods using MR2150